CATHACTION Evaluation Protocol

Draft of 2026/11/29, replacing the protocol of 2026/10/07. Takes effect when the online evaluation server opens.

  1. Overview
  2. Accounts
  3. What to submit
  4. Submission frequency
  5. Official container evaluation
  6. Publication
  7. Training data audit
  8. Eligibility and updates

1. Overview

The CATHACTION organisers maintain this leaderboard across all tracks and challenge editions. Test labels are never released, and every score on the leaderboard is computed by the organisers with the same scoring code. Track: CATHACTION-Seg (catheter and guidewire segmentation). Entries from the MICCAI 2026 Challenge and from open submissions share one leaderboard, and the source of each entry is shown.

2. Accounts

  • Submissions are made through the online evaluation server. Register with an institutional email address; accounts are approved by hand.
  • One account per research group and method family. Using several accounts to get around the submission limit leads to removal of all entries from those accounts.
  • Participants who can not use the online server may email their submission to the leaderboard manager; the same rules apply.

3. What to Submit

  • A Docker image (file from docker save) as a Google Drive link or any other direct download link without speed limits.
  • The container runs offline. Input /input/image.nii.gz, a stack of 2D X-ray frames; output /output/segmentation.nii.gz of the same size. Labels: 0 background, 1 catheter, 2 guidewire.
  • Method name, team name, a short method description, and a complete list of training data including external and private data.

4. Submission Frequency

  • Each account may submit once every 3 days. Submissions that fail before scoring starts (broken link, image does not load, wrong output format on the first sequence) do not count.
  • The test set must not be used for model selection. Use the public validation split for development.

5. Official Container Evaluation: CATHACTION-Seg

  • Human test set: 11,723 frames, 241 sequences, 4 hospitals (CLY, DHW, HTM, HXS). Animal and phantom test set: 4,691 frames (animal 1,006, phantom 3,685).
  • Ranking metric: case-macro Dice on the human test set. Also reported: clDice, precision, recall, HD95, empty prediction rate and per-site Dice.
  • Hardware: one NVIDIA RTX 3090 (24 GB), 32 GB RAM, no network. Each sequence must finish within 10 minutes. Runtime per frame is reported.
  • Results, including per-site scores, are shown privately to the submitting account. Per-frame results are not returned.

6. Publication

  • Results are private by default. The submitting account decides when to publish an entry.
  • Entries may be published anonymously while the corresponding paper is under double-blind review; name and paper link are added after acceptance.
  • A published entry is shown as "Pending" until the training data audit is passed, then as a verified entry.
  • Teams may withdraw a published entry at any time. Each entry shows its evaluation date; new entries are announced in News.

7. Training Data Audit

  • The declared training data is checked against the submitted image.
  • Performance on public training data and on the test set is compared to detect use of test labels.
  • The training data category is shown on the leaderboard: human, animal and phantom only, or not declared.

8. Eligibility and Updates

  • Undeclared training data, use of test labels or multiple accounts lead to removal from the leaderboard.
  • The organisers may revise this protocol. Changes are dated on this page and announced in News.
  • Contact: Baoru Huang (leaderboard manager), baoru.huang@liverpool.ac.uk; Qi Shao (lead), shaoqi@liverpool.ac.uk.